Product ID: CY-6465


Salt Spray Testing Equipment


Salt water spray test device: This device is used to test the surface treatment
of various materials. The so-called treatments include coating, coating
electroplating films of organic and non-organic materials, anodizing, anti-rest oil
and corrosion resistant treatment, which may achieve the purpose of keeping the
items from being corroded for a longer period.



click on the photo to close this window
Salt Spray Testing Equipment

Click here for details.

Specifications:


  • Specification:
    • TEST APPLIACABLE: NSS , ACSS , CASS.
    • TEST TEMPERATURE: 35ˇÓ1˘J or 50ˇÓ1˘J.
    • INSIDE DIMENSION: 450 x 600 x 400 (DxWxH)m/m.
    • OUTSIDE DIMENSION: 760 x 1140 x 1190 (DxWxH)m/m.
    • VOLUME: 108 LITER.
    • WEIGHT: 60 KGW.
    • TEST SPECIMEN
    • 15˘X: 24 PCS.
    • TEST SPECIMEN
    • 30˘X: 15 PCS.
    • SOLUTION TANK CAPACITY: 15 LITER.
    • SOLUTION TANK TESTING TIME: 90 HR.
    • POWER CONSUMPTION: 220V SINGLE PHASE 3KW.

Features:


  • Features:
    • A. The whole part of the device is made of P.V.C. sheet and the inside of the
    • device is reinforced by using a special lining material. Hence, it is sturdily
    • made and will not transform forever.
    • B. The test chamber is heated from five directions in order to ensure the
    • temperature difference in the chamber may be kept within(+)(-)1 Celsius
    • degree.
    • C. Spray nozzle: The nozzle is specially made to enable it to suck up the salt
    • Water and then spray it out in the shape of mist with considerable high
    • speed. When it falls on the surface of the item being tested , the difference
    • of fallen mist may be controlled within(+)/(-)0.3ml per 80 square centimeter
    • H.
    • D.HUNTER PRINCIPLE is used to make the saturated air hot and moist and to
    • keep the humidity in the test chamber required for test.
    • E. Temperature is the pre-requisite condition that will have direct impact on
    • corrosion rate . We use P.I.D. temperature control unit to limit the
    • temperature difference within the range of (+)(-)0.5 Celsius degree.
    • F. A warning device is used to indicate the low level of the test fluid. When the
    • fluid is only enough for being sprayed for five hours , a buzzer will remind the
    • user to replenish the liquid to ensure continuous spray test.
    • G. Digital Display Time ControllerˇG9.9S-9990HR ANLY AH5R

Ordering information:

  • Minimum Order: Negotiable
  • TEL: 886-4-26391141
  • FAX: 886-4-26392354




Copyright (C) Chun Yen Testing Machines Co., Ltd.. All rights reserved.


Commerce Site .